Battery charge and discharge tester

Short Description:

EquipmentSpecifications 5V/10A Device channel number 8 Channel control mode Independent control for each channel, current and voltage four-wire system collection Channel characteristics Constant current source and constant voltage source adopt double closed loop structure  Input impedance ≥1MΩ Voltage Voltage range   Recharge 10mV-5V(Device port) Discharge 1V-5V(Device port),the minimum discharge voltage is related to the line length accuracy ±0.1% of FS, ambi...


Product Detail

Product Tags

EquipmentSpecifications 5V/10A
Device channel number 8
Channel control mode Independent control for each channel, current and voltage four-wire system collection
Channel characteristics Constant current source and constant voltage source adopt double closed loop structure 
Input impedance ≥1MΩ

Voltage

Voltage

range

 

Recharge 10mV-5V(Device port)
Discharge 1V-5V(Device port),the minimum discharge voltage is related to the line length
accuracy ±0.1% of FS, ambient temperature15℃-35℃
Current

Voltage

range

 

Recharge 20mA-10A
Discharge 20mA-10A
accuracy ±0.1% of FS , ambient temperature15℃-35℃
power Single channel output power 50W
stability 0.2% of FS
Time Current response time ≤10ms
Datarecord Recording frequency 1Hz
Data recording conditions Minimum time interval: 1S
Minimum voltage interval: 1mV
Minimum current interval: 1mA
Recharge Charging mode Constant current charging, constant voltage charging, constant current constant voltage charging, constant power charging
Cut-off condition Voltage, current, relative time, capacity, -△V
Discharge Discharge mode Constant current discharge, constant power discharge, constant resistance discharge
Cut-off condition Voltage, current, relative time, capacity, -△V
Pulse mode 

Optional

Recharge Constant current mode, constant power mode
Discharge Constant current mode, constant power mode
Minimum pulse width Recommended above 5S
Cut-off condition Voltage, relative time
DCIR DCIR Optional) Support custom pick points for DCIR calculation
cycle Loop test 399 commands can be set, 65535 cycles can be set
Loop nesting Support 5 levels of loop nesting
protection Software protection Support power-down data protection
Support continuous start (should have UPS power supply)
Overvoltage protection, undervoltage protection, capacity protection, overcurrent protection, undercurrent protection
Anti-reverse protection
Data export method ExcelPDF
cooling method Wind cooling
Equipment noise ≤60dB
Communication with host computer Internet
Dimensions
Display screen
System Requirements windowsXP and above

6 7 8 9 10 11 12微信图片_20210721145251


  • Previous:
  • Next:

  • Write your message here and send it to us
    WhatsApp Online Chat !