Battery pack bottom acupuncture testing machine price battery pack bottom acupuncture testing machine manufacturer
Product name: battery pack bottom stab test system (customized)
Product use: The battery pack bottom ten thorn test system (customized model) is to install the battery pack with a crane or another vehicle; the whole system is remotely controlled by a computer, safe and reliable, and the console, battery pack bracket, and bottom ten thorns can be moved independently do not affect each other,
The mutual power lines, signal lines, etc. need to be waterproof and flame retardant, and at the same time, they are designed to be easily and quickly inserted, which is easy to disassemble and assemble.
Bottom acupuncture host | |
Acupuncture structure | Servo motor screw drive structure can be adjusted frombottom to top for acupuncture test 0-20kN |
Needling direction | 0.4%FSR |
power range | 0.1mm/s -25mm/s (speed adjustable) relative error <0.5%FS |
Force value accuracy | Relative error <0.5%Fs |
Needling speed | 0-300mm |
Speed accuracy | Structural design for easy installation and removal |
Acupuncture displacement accuracy | Relative error <0.5%Fs |
Needling displacement (B axis) | 0-300mm |
Installation of steel needles | Structural design for easy installation and removal |
battery pack holder | |
size | Meet the largest size: PACK installation of W1600*D2300mm |
quantity | 2 sets |
load bearing | 1t |
Anti-rust and anti-corrosion treatment | It needs anti-rust, fire-proof and corrosion-resistant treatment; it should be easy to clean after the test is completed |
Temperature and voltage acquisition | |
temperature acquisition channel | 20 (adapted to the initial sensor) |
Temperature measurement range | 0~1500℃, equipped with high temperature resistantmining temperature line 500℃, 20 pieces |
temperature accuracy | ±1℃ |
Temperature acquisition rate | 20Hz |
Voltage acquisition channel | 2 |
voltage range | 0~1000V, equipped with high temperature resistantmining pressure line 500℃, 2 pieces |
Voltage accuracy | 100Hz |
Voltage acquisition rate | 0.5%FSR |
Monitoring system of battery packbottom needle prick test system | ||
System composition | Monitoring system of battery pack bottom needle pricktest system | |
1 monitor (display large screen), 1 hard disk video recorder(4 channels, | ||
Including 1 1T hard disk, 4 cameras |
Equipment control operation cabinet | |
size | Reference: W850 x D650xH1200mm(customizable) |
computer host | Lenovo host, system: WIN7, CPU: i5, |
Running memory: 4G, hard disk: 1t+256SSD; Lenovo display:21 inches |
test system | |
Remote control distance | The distance between the control computer cabinet and thetransmission host can be controlled at more than 10 meters
by the network cable. Put the control computer cabinet on a separate site and isolate it from the acupuncture host to ensure safe operation. |
How software is tested | program mode; fixed value mode |
Synchronized output graphics | High-speed synchronous dynamic acquisition of data anddynamic plotting of curves |
Calibration function | The test software has the function of calibrating physicalquantities such as force, displacement speed, time, total
voltage, auxiliary temperature, etc., so as to calibrate the deviation of these physical quantities |
safety design | There is an emergency stop switch on the computer cabinet,which can stop the entire test in an emergency |
Equipment operation safety reminder | The equipment is equipped with three-color alarm lights to remind personnel of the current testrunning status of the equipment. Avoid misuse |