Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin

Short Description:

Product Description The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system. 1. The aerosol emitted by the aerosol ...


Product Detail

Product Tags

Related Video

Feedback (2)

we are able to supply top quality items, aggressive price and greatest buyer assistance. Our destination is "You come here with difficulty and we offer you a smile to take away" for Ozone Aging Tester Chamber , high-low temperature test chamber , thermal cooling chamber , Quality is factory's lifestyle , Focus on customers' demand could be the source of corporation survival and advancement, We adhere to honesty and great faith operating attitude, looking ahead on your coming !
Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin Detail:

Product Description

The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor. The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor.

 

6445980011


Product detail pictures:

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures


Related Product Guide:
Cooperation

Our primary goal is to offer our clients a serious and responsible business relationship, providing personalized attention to all of them for Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin , The product will supply to all over the world, such as: Seychelles , Philadelphia , Romania , Our company has already had a lot of top factories and professional technology teams in China, offering the best products, techniques and services to worldwide customers. Honesty is our principle, professional operation is our work, service is our goal, and customers' satisfaction is our future!
Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
5 Stars By Leona from Iran - 2017.09.30 16:36
Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
5 Stars By Rosalind from Ghana - 2018.11.28 16:25
Write your message here and send it to us
WhatsApp Online Chat !