Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin

Short Description:

Product Description The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system. 1. The aerosol emitted by the aerosol ...


Product Detail

Product Tags

Related Video

Feedback (2)

Our target is to consolidate and improve the quality and service of existing products, meanwhile constantly develop new products to meet different customers' demands for Electronic Temperature Thermal Shock Stability Test Chamber , Electronic Uv Aging Climatic Environmental Tester , Salt Spray Corrosion Tester , We are glad that we are steadily growing with the active and long term support of our satisfied customers!
Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin Detail:

Product Description

The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor. The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor.

 

6445980011


Product detail pictures:

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures


Related Product Guide:
Cooperation

As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin , The product will supply to all over the world, such as: Macedonia , Detroit , Australia , We aim to become the modern enterprise with the commercial ideal of "Sincerity and confidence" and with the aim of "Offering customers the most sincere services and best quality products". We sincerely ask for your unchanged support and appreciate your kind advice and guidance.
This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
5 Stars By Dolores from Rio de Janeiro - 2018.06.18 17:25
The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
5 Stars By Helen from France - 2018.12.25 12:43
Write your message here and send it to us
WhatsApp Online Chat !