Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin

Short Description:

Product Description The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system. 1. The aerosol emitted by the aerosol ...


Product Detail

Product Tags

Related Video

Feedback (2)

"Based on domestic market and expand overseas business" is our improvement strategy for Long Arc Xenon Lamp Test Machine , Solar Radiation Uv Accelerated Weathering Tester , Environmental Thermal Shock Test Machine , Welcome friends from all over the world come to visit, guide and negotiate.
Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin Detail:

Product Description

The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor. The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor.

 

6445980011


Product detail pictures:

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures


Related Product Guide:
Cooperation

"Quality initial, Honesty as base, Sincere support and mutual profit" is our idea, so as to build repeatedly and pursue the excellence for Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin , The product will supply to all over the world, such as: United States , Bandung , Dominica , We have been perfectly devoted to the design, R&D, manufacture, sale and service of hair products during 10 years of development. We have introduced and are making full use of internationally advanced technology and equipment, with advantages of skilled workers. "Dedicated to providing reliable customer service" is our aim. We are sincerely looking forward to establishing business relationships with friends from at home and abroad.
The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
5 Stars By Dawn from Serbia - 2018.06.05 13:10
A good manufacturers, we have cooperated twice, good quality and good service attitude.
5 Stars By Daniel Coppin from Zurich - 2018.06.12 16:22
Write your message here and send it to us