Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin

Short Description:

Product Description The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system. 1. The aerosol emitted by the aerosol ...


Product Detail

Product Tags

Related Video

Feedback (2)

We usually perform being a tangible workforce making sure that we will give you the most beneficial excellent plus the finest selling price for Vibrating Machine , temperature climatic chamber , Paint Plastic Xenon Test Chamber , Any interest, make sure you really feel free to get hold of us. We're searching forward to forming prosperous enterprise interactions with new purchasers across the earth within the near upcoming.
Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin Detail:

Product Description

The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor. The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor.

 

6445980011


Product detail pictures:

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures


Related Product Guide:
Cooperation

We emphasize enhancement and introduce new solutions into the market just about every year for Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin , The product will supply to all over the world, such as: Palestine , Bahrain , Bulgaria , Our company always committed to meet your quality demand, price points and sales target. Warmly welcome you open the boundaries of communication. It is our great pleasure to service you if you need a trusted supplier and value information.
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Juliet from Florida - 2017.04.18 16:45
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Carol from Denmark - 2018.10.01 14:14
    Write your message here and send it to us
    WhatsApp Online Chat !