Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin

Short Description:

Product Description The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system. 1. The aerosol emitted by the aerosol ...


Product Detail

Product Tags

Related Video

Feedback (2)

All we do is usually affiliated with our tenet " Buyer to start with, Belief to start with, devoting about the food packaging and environmental defense for high-low temperature and humidity chamber , Tensile Strength Testing Machine Price , Tensile Test Machine , We welcome all of the purchasers and pals to contact us for mutual added benefits. Hope to do additional business enterprise along with you.
Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin Detail:

Product Description

The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor. The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor.

 

6445980011


Product detail pictures:

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures

Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester  – Hongjin detail pictures


Related Product Guide:
Cooperation

"Based on domestic market and expand overseas business" is our improvement strategy for Good Quality Electrical Test – HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester – Hongjin , The product will supply to all over the world, such as: Russia , Nicaragua , Congo , The company has perfect management system and after-sales service system. We devote ourselves to building a pioneer in the filter industry. Our factory is willing to cooperate with different customers domestic and overseas to gain better and better future.
  • Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Gabrielle from Canada - 2018.06.26 19:27
    We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
    5 Stars By Gemma from Libya - 2017.06.22 12:49
    Write your message here and send it to us
    WhatsApp Online Chat !