Good Quality Electrical Test – medical face mask filtration efficiency tester (HY-CO2) – Hongjin

Short Description:

Product Profile HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester is mainly used for the filtration efficiency detection of masks. The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that m...


Product Detail

Product Tags

Related Video

Feedback (2)

Responsible excellent and fantastic credit rating standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality initial, buyer supreme" for Electronic Temperature Humidity Testing Equipment , high low temperature climate test chamber , Xenon Lamp Accelerated Aging Test Chamber , For further inquires please do not hesitate to contact us. Thank you - Your support continuously inspires us.
Good Quality Electrical Test – medical face mask filtration efficiency tester (HY-CO2) – Hongjin Detail:

Product Profile

HY-CO2 Medical 3d Face Mask PFE Particulate Filtration Efficiency Tester is mainly used for the filtration efficiency detection of masks.

The mask filter performance tester cleans the compressed air and sprays the pre-prepared NaCl solution or DEHS / PAO and other similar solutions from the aerosol generator. After passing through a classifier (inertial principle), the large particles that are not needed are collected into the collection bottle inside, aerosol particles that meet the requirements are ejected from the nozzle of the aerosol generator into the test system.

1. The aerosol emitted by the aerosol generator needs to undergo two treatments before reaching the test filter material;
a. Produce aerosol salt particles by mixing with heated gas (for salt spray). b. Neutralize the static electricity carried by the aerosol through an electrostatic neutralizer. This action is to reduce the loss of particles and the influence of static electricity on the test results.
2. After being processed by the above two procedures, the aerosol reaches the surface of the test filter material at a certain flow rate (flow rate) and begins the test procedure. For the filtration efficiency test, the test time is very short, and it takes only a few seconds to complete the test of one filter material. For the loading experiment test, the loading experiment is relatively long. The aerosol quantity concentration or mass concentration in the upstream and downstream of the filter material is measured by a particle counter or a laser scattering photometer, and the filtration efficiency is calculated. Meanwhile, the pressure drop on both sides of the filter material is monitored by a pressure difference sensor.

6445980011QQ图片20190724094356HJ-5


Product detail pictures:

Good Quality Electrical Test –  medical face mask filtration efficiency tester (HY-CO2) – Hongjin detail pictures

Good Quality Electrical Test –  medical face mask filtration efficiency tester (HY-CO2) – Hongjin detail pictures

Good Quality Electrical Test –  medical face mask filtration efficiency tester (HY-CO2) – Hongjin detail pictures

Good Quality Electrical Test –  medical face mask filtration efficiency tester (HY-CO2) – Hongjin detail pictures

Good Quality Electrical Test –  medical face mask filtration efficiency tester (HY-CO2) – Hongjin detail pictures

Good Quality Electrical Test –  medical face mask filtration efficiency tester (HY-CO2) – Hongjin detail pictures

Good Quality Electrical Test –  medical face mask filtration efficiency tester (HY-CO2) – Hongjin detail pictures


Related Product Guide:
Cooperation

To fulfill the customers' over-expected fulfillment , we have now our solid staff to deliver our greatest general assistance which includes internet marketing, product sales, creating, manufacturing, excellent controlling, packing, warehousing and logistics for Good Quality Electrical Test – medical face mask filtration efficiency tester (HY-CO2) – Hongjin , The product will supply to all over the world, such as: luzern , Congo , Hyderabad , Our company, is always regarding quality as company' s foundation, seeking for development via high degree of credibility , abiding by iso9000 quality management standard strictly , creating top-ranking company by spirit of progress-marking honesty and optimism.
  • The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Henry stokeld from Nairobi - 2018.10.01 14:14
    The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
    5 Stars By Ivan from Ghana - 2018.11.04 10:32
    Write your message here and send it to us
    WhatsApp Online Chat !