Product description
This device complies with the requirements of GB2423.55-2006, GBT20138-2006, IEC61439-12009, IEC62262-2002 Article 6 and IEC60068-2-75 and other standards for test equipment, and is suitable for the mechanical impact strength of electrical equipment enclosures to the outside world Grade test. The device is made of stainless steel frame welded and formed, the structure is compact and durable, the mounting bracket is adjustable up and down, the impact angle is adjustable from 0-90°, and the operation is convenient.
Technical parameter | |
Power supply | 220V50Hz |
Swing angle | 0-90° adjustable, scale display |
Swing rod length | 1000mm |
Configure the hammer | 1J, 2J, 5J, 10J, 20J, 50J hammer heads each (optional, specified on the order), each connected to the pendulum rod; |
Correspondence table of IK codes and their corresponding collision energies | ||||||||||
IK code | IK01 | IK 02 | IK 03 | IK 04 | IK 05 | IK 06 | IK 07 | IK 08 | IK 09 | IK 10 |
Collision energy/J | 0.14 | 0.2 | 0.35 | 0.5 | 0.7 | 1 | 2 | 5 | 10 | 20 |
Note 1 If higher collision energy is required, the recommended value is 50J |
The impact test height is 200-1200mm, electrically adjustable, and the equipment height is 2.6 meters;
Impact energy, equivalent mass and drop height comparison table | ||||||||||
energy/J | 0.14 | 0.2 | 0.35 | 0.5 | 0.7 | 1 | 2 | 5 | 10 | 20 |
Equivalent mass/kg (±2%) | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.5 | 1.7 | 5 | 5 |
Drop height (±1%/mm) | 56 | 80 | 140 | 200 | 280 | 400 | 400 | 300 | 200 | 400 |
Hammer head standard and reference size (length varies according to equivalent quality requirements) | ||||||
Energy/J | ≤1 | 2 | 5 | 10 | 20 | 50 |
±10% | ±5% | ±5% | ±5% | ±5% | ±5% | |
Equivalent mass±2%kg | 0.25(0.2) | 0.5 | 1.7 | 5 | 5 | 10 |
Material | Nylon | Steel | ||||
R/mm | 10 | 25 | 25 | 50 | 50 | 50 |
D/mm | 18.5 (20) | 35 | 60 | 80 | 100 | 125 |
Ff/mm | 6.2 (10) | 7 | 10 | 20 | 20 | 25 |
R/mm | - | - | 6 | - | 10 | 17 |
L/mm | Determined by Equivalent Mass Adjustment, see Appendix A | |||||
NOTE When the energy is less than or equal to 1 J, the equivalent mass of the striking element and the diameter of the striking element in parentheses are referenced to the original test Ef, and the magnitude of the test Eg has been included in this parameter. |