UV Aging Tester
The main function:
The UV-uv tester for plastic uses imported UVA-340 fluorescent UV light as a light source to simulate the damage caused by sunlight, rain and dew. The UV weatherproof box uses a fluorescent UV lamp to simulate the effect of sunlight, and uses condensed moisture to simulate dew. The material to be tested is placed in a loop program of alternating light and moisture at a certain temperature to accelerate the weathering test of the material to obtain the weather resistance of the material. The UV box can reproduce the hazards of outdoor months or years in days or weeks. Types of hazards include: fading, discoloration, loss of light, powdering, cracking, turbidity, air bubbles, embrittlement, strength, decay, and oxidation. This machine contains a shower device.
The ultraviolet uv tester for plastic can simulate environmental conditions such as ultraviolet, rain, high temperature, high humidity, condensation, darkness and the like in a natural climate, and by recreating these conditions, merge them into a loop, and let it automatically perform the loop. frequency. This is how the uv curing aging testing works. In this process, the equipment can automatically monitor the temperature of the blackboard and the temperature of the water tank. By configuring the irradiance measurement and control device (optional), the irradiance can be measured and controlled to stabilize the irradiance at 0.76W/m2/340nm or Specify the set value and greatly extend the life of the lamp.
In line with international standards:
ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE, J2020, ISO 4892 All current UV aging test standards.
Light source:
The light source uses 8 imported UV fluorescent lamps with a rated power of 40W as the light source. Ultraviolet fluorescent tubes are distributed on both sides of the machine, 4 on each side. There are UVA-340 and UVB-313 light sources for users to choose from. The luminescence spectrum energy of the UVA-340 lamp is mainly concentrated at the wavelength of 340 nm, and the luminescence spectrum of the UVB-313 lamp is mainly concentrated near the wavelength of 313 nm. We use the UVA-340 lamp because the fluorescent light energy output will gradually decay with time. In order to reduce the impact of the test due to the attenuation of light energy, this test box is every 1/1 of all eight lamps. When the fluorescent lamp of 4 is used, an old lamp is replaced by a new lamp, so that the ultraviolet light source is always composed of a new lamp and an old lamp, thereby obtaining a constant output light energy. The effective life of the lamp can be around 1600 hours.
Power control:
a. Blackboard temperature and condensing temperature are controlled by controller.
b. The rest basically use imported electronic components.
Uniformity of irradiance: ≤ 4% (at the surface of the sample)
Blackboard temperature monitoring: The standard Pt-100 blackboard temperature sensor is used to precisely control the sample surface temperature during the test.
Blackboard temperature setting range: BPT 40-75 °C; but the actual maximum temperature limit of the internal temperature protection device is 93 °C ± 10%.
Blackboard temperature control accuracy: ±0.5 °C,
c. Sink temperature monitoring: During the loop test, one test section is a dark condensation process, which requires a saturated water vapor that can generate a higher temperature in the tank. When the water vapor encounters a relatively cold surface of the sample, Dew will condense on the surface of the sample. The sink is located in the lower part of the cabinet and has an electric heater.
Sink temperature control range: 40~60°C
d, the test box is equipped with a time controller, the range is 0~530H, power failure memory function.
e, safety protection device:
Over temperature protection inside the box: When the temperature inside the box exceeds 93 °C ± 10%, the machine will automatically cut off the power supply of the lamp and heater, and enter the equilibrium state to cool.
The low water level alarm in the sink prevents the heater from being burned.
High Performan Stainless steel uv weathering test machine pric
Model |
HY-1020 |
HY-1021 |
Studio Size |
W1170*H450*D500mm |
W1150 X H400 x D400mm |
Outside dimension |
W1300×H550×D1480mm |
W1400 X H1450 x D650mm |
Temperature range |
RT+10~70°C |
|
Temperature uniformity |
±2°C |
|
Temperature fluctuation |
±0.5°C |
|
Testing time |
0~999H, adjustable |
|
Materials |
Inside and Outside SUS#304 stainless steel |
|
Humidity range |
≥90%RH |
|
Controller |
Korean TEMI programmable controller |
|
Lamp power |
40W/Piece |
|
Test cycle setting |
Illumination, condensation and water spray test cycle is programmable |
|
Irradiance |
1.0W/m2 |
|
Wavelength ultraviolet light |
UV-A: 315-400nm; UV-B: 280-315nm (8pcs, 1600h lifetime) |
|
Distance from sample to lamp |
50±2mm (adjustable) |
|
Centre distance between the lamp |
70mm |
|
Standard Specimen Size |
75×150mm or 75×3000mm (special specitications to be described in the contact) |
|
Required water depth for water channel |
25mm, automatically control |
|
Protection system |
Overload short circuit protection, over temperature protection, water lackin |
|
Power |
220V/50Hz /±10% 4.5KW |
Production process:
1. Are your company a trading one or a factory?
Factory ,13years focusing on test instruments field,3 years exporting experience.Our factory is in Dongguan, Guangdong, China
2. After an order is placed, when to deliver?
Usually about 15 working days, if we have finished products, we can arrange delivery within 3 working days.
Please note that our production lead time depends on the specific project and the number of projects.
3. What about the warranty with after – sales services?
12 months warranty.
After the warranty, the professional after-sales service team will provide comprehensive technical support to help customers solve problems encountered when using our products, and promptly handle customer problems and complaints.
4. What about the services and product’ quality?
Service: ,Design service,Buyer lable service.
Quality: Each instruments must be carried out 100% quality examination and test, the finished products must through a third party calibration institutions before shipping and delivery goods.